Frequently Asked Questions

LK50D1 Deluxe Finger Pulse Oximeter


Questions

General Questions

What does the LOOKEE® LK50D1 Deluxe do?

It measures oxygen saturation (SpO₂) and pulse rate (PR) via a fingertip sensor, showing the results on an OLED screen.

Who can use it?

It is suitable for adults and children over 4 years old (weighing 15 to 110 kg). Not suitable for infants or newborns.

Can I use this device for diagnosis or medical treatment?

No. It is designed for monitoring only, not treatment or life-supporting functions.

Is it safe to use continuously?

Avoid using it on the same finger for more than 2 hours, especially for people with poor circulation.

Can I use nail polish or long nails?

No. Nail polish, artificial nails, or long nails can block the sensor and cause inaccurate readings.

How do I power the device?

Insert two AAA batteries following the correct polarity. Replace the cover before use.

How do I operate it?
  • Insert two AAA batteries.
  • Open the clip and insert your finger (nail facing the display).
  • Press the power button once.
  • Remain still until readings stabilize.
  • The device auto shuts off after 5 seconds with no signal.
What does the display show?
  • SpO₂ (%)
  • PR (bpm)
  • Pulse waveform
  • Bar graph intensity
  • Low battery indicator
Can I adjust brightness?

Yes. When powered on, press and hold the button to adjust brightness.

How do I change the screen orientation on my LOOKEE® LK50D1 Deluxe?

The LOOKEE® LK50D1 Deluxe features an auto-rotating display, which automatically adjusts the screen orientation depending on how you hold the device.

What are the measurement ranges and accuracy?

Parameter

  • SpO₂
  • Pulse Rate

Range

  • 0 to 100%
  • 30 to 250 bpm

Accuracy

  • ±2% (70 to 100%),
  • ±2 bpm or ±2% (whichever is greater)
What affects reading accuracy?
  • Improper finger placement
  • Motion or shaking
  • Cold fingers / poor circulation • Strong ambient light
  • Nail polish or artificial nails
  • Certain medications (e.g., dyes or vasoconstrictors)
How should I clean and disinfect it?
  • Wipe surface with medical alcohol and dry with a clean cloth.
  • Do not use high-pressure steam or immerse in liquids.
  • Remove batteries if storing long-term.
Does the LOOKEE® LK50D1 Deluxe have an alarm feature?

No, the LOOKEE® LK50D1 Deluxe does not have an alarm feature.

It is designed primarily for spot checking and short-term monitoring, showing your SpO₂, pulse rate, and pulse waveform on the display.

If you need a device with an audio/visual alarm that alerts you when your oxygen level or heart rate goes above or below preset thresholds, we recommend the LOOKEE® A320 or A320B, which include this alarm function. In Canada, the A310 has it too.

Why is there no display or no readings showing on my oximeter?

Possible Cause:

Your finger may not be positioned properly, or your SpO₂ level may be too low to detect.

Solution:

Reinsert your finger fully and try again. If the issue persists, consult your physician to ensure proper circulation and oxygen level.

Why are my readings unstable or fluctuating?

Possible Cause:

The finger may be moving or not inserted deep enough into the sensor clip.

Solution:

Keep your finger still and properly inserted during measurement. Avoid shaking or movement for the most accurate readings.

Why won’t my oximeter turn on?

Possible Cause:

The batteries may be dead, incorrectly installed, or there could be an internal device fault.

Solution:

Replace or reinstall the batteries correctly. If the device still does not power on, contact customer support at Support@LookeeTech.com