Frequently Asked Questions
A310 & A310L Premium Fingertip Pulse Oximeter
Questions
General Questions
What is the difference between the LOOKEE® A310 and A310L?
The LOOKEE® A310 and A310L are essentially the same product. They share the same features, parts, and firmware. The only difference is the colour:
- A310 comes in blue.
- A310L comes in black.
Both models include:
- An alarm feature that sounds when oxygen saturation (SpO₂) or heart rate (PR) goes below or above the preset threshold.
- A Perfusion Index (PI) display that indicates pulse strength.
- Ideal use for spot checking and short-term monitoring.
What does the LOOKEE® A310 measure?
It measures oxygen saturation (SpO₂) and pulse rate (PR) using a fingertip sensor.
Who can use this device?
The A310 is suitable for adults and children over 3 years old. It should not be used on children below 3 years as results may be inaccurate.
Is this device intended for medical treatment?
No. It is a monitoring and screening tool, not for medical diagnosis or treatment decisions.
Where can I use it?
It’s suitable for home, hospital, and clinical settings (e.g., surgery, anesthesia, pediatrics, ICU, oxygen bars, sports health monitoring).
How long can I use it continuously?
The A310 is meant for spot checks and short-term monitoring, not continuous 24-hour use.
What type of batteries does it use?
Two AAA 1.5V alkaline batteries, providing 20+ hours of continuous operation.
How do I turn it on and off?
- Press the power button to turn it on.
- It will auto power off if no finger is detected for more than 16 seconds.
What information appears on the display?
The colour OLED display shows:
- SpO₂ (%)
- Pulse Rate (bpm)
- Plethysmogram waveform
- Perfusion Index (PI)
- Low battery indicator
Can I adjust the screen settings?
Yes. Hold the direction button for 1 second to enter the menu:
- Sound Reminder: On/Off
- Beep: On/Off
- Brightness: Levels 1 to 5
- Restore: Factory reset
- Demo Mode: On/Off
How do I change the screen orientation on my LOOKEE® A310?
The LOOKEE® A310 allows you to manually change the screen orientation so you can view your readings from different angles.
To change the orientation:
- While the device is on and displaying readings, press and hold the direction button for about one second.
- The display will rotate to the next viewing position.
- Repeat the step to cycle through all available orientations until you reach your preferred one.
What are the measurement ranges and accuracy?
Parameter
- SpO₂
- Pulse Rate
- Perfusion Index
Range
- 35 to 100%
- 30 to 250 bpm
- 0 to 20%
Accuracy
- ±2% (90 to 100%), ±3% (70 to 90%)
- ±1 bpm
- ±1%
Why is there no reading (SpO₂ or PR) on my oximeter?
Possible Cause:
Your finger may not be fully inserted, or there may be poor blood circulation (low perfusion).
Solution:
Reinsert your finger completely or try a different finger. If readings are still unstable, consult your doctor for further evaluation.
Why are my readings unstable or fluctuating?
Possible Cause:
Movement or hand trembling during measurement can cause unstable readings.
Solution:
Keep your hand and body still while taking measurements, and retry.
Why do I get abnormal results or hear an alarm sound?
Possible Cause:
The finger might not be positioned correctly, or your actual oxygen level (SpO₂) may be low.
Solution:
Reinsert your finger properly and take another measurement. If abnormal readings persist, seek medical advice.
Why won’t my oximeter power on?
Possible Cause:
The batteries may be drained, incorrectly installed, or the device could be damaged.
Solution:
Replace or reinstall the batteries correctly. If the device still does not turn on, contact customer service for assistance at Support@LookeeTech.com
Why does the screen turn off suddenly?
Possible Cause:
The oximeter automatically powers off when not in use, or the battery is low.
Solution:
This is normal. If it turns off too quickly, replace the batteries.
Why is the battery symbol blinking?
Possible Cause:
Battery power is running low.
Solution:
Replace both AAA batteries with new ones.